Call us : +919895284319   |   E-Mail : sales@ipcsautomation.com
ipcs facebook ipcs twitter ipcs linkedin ipcs google plus ipcs youtube ipcs rss feed ipcs blog

PRODUCTS SOLUTIONS Product Enquiry

HVI Lightning Protection, CUI Conductor |  Conductors |  Air-termination Systems and Accessories |  Isolated Lightning Protection |  Roof Conductor Holders and Wall Conductor Holders |  Connecting Components |  Components for Foundation Earth Electrodes and Earth Rods |  Equipotential Bonding |  Tools, Measuring Equipment and Accessories |  Special Application

HVI Lightning Protection, CUI Conductor

High-voltage-resistant insulated HVI® and CUI Conductors allow to keep the separation distance from conductive parts and to control touch voltage on down conductors.

HVI®light Conductor

HVI®light ConductorSystem to maintain the separation distance e.g. on flat roofs. The high-voltage-resistant, insulated HVI light Conductor prevents uncontrolled flashover to metal or electric components underneath the roofing.

For use up to an equivalent seaparation distance s ≤ 45 cm (in air) or s ≤ 90 cm (solid material).

Air-termination Masts for HVI®light Conductor on Flat Roofs

Air-termination Masts for HVI®light Conductor on Flat RoofsComplete with connection plate plate for four HVI light Conductors and fixing kit for mounting the conductors at the air-termination mast. Adjustable to roof inclination up to max. 10°.
The concrete bases (weight 17 kg) and support plates have to be ordered separately.

DEHNcon-H

DEHNcon-HInsulated air-termination system for transmitters/receivers (satellite dish, terrestrial antenna) or whole buildings or parts of a building. Aesthetically appealing due to the HVI light Conductor being installed inside of the supporting tube, reduced size of the supporting tubes (Al pipe 40 x 5 mm / GRP tube 30 x 3 mm) and light total weight, also suitable for subsequent mounting at antenna poles. Special interior sealing end provides a flexible StSt strip led out at the lower end of the supporting tube for connection to the equipotential bonding system of the building.

Air-termination Masts for Sub-roof Installation of the HVI®Conductor

Air-termination Masts for Sub-roof Installation of the HVI®ConductorFor attaching on the mounting bracket for use at rafters.
Aesthetically appealing installation of the HVI Conductor or HVI light Conductor inside of the supporting tube. The HVI Conductors are ducted through the supporting tube of the mounting bracket for rafters and installed in the area of the counter-battens/roof battens. Advantages:
Sub-roof installation – not visible
Only the supporting tube is visible
No mechanical loading e.g. by snow

Mounting Bracket for Use at Rafters

Mounting Bracket for Use at RaftersFor lateral fixing of the DEHNcon-H supporting tube (Ø40 mm) HVI Conductor inside of the supporting tube (Ø50 mm) as well as for attaching and fixing of the supporting tubes and for the sub-roof installation of the HVI Conductor or HVI light Conductor.

Supporting Tube with HVI®Conductor

Supporting Tube with HVI®ConductorVisually appealing installation of HVI Conductor inside of the supporting tube with small wind exposed surface area. For use up to an equivalent separation distance s ≤ 75 cm (in air) or s ≤ 150 cm (solid material). Conductor length to be indicated when ordering (steps of 0.5 m).

Air-termination Mast with HVI®Conductor

Air-termination Mast with HVI®ConductorFor a maximum free length of the whole air-termination system of 8.5 m. To be fixed with three variable supports (Part No. 105 345). Transport length 6000 mm

HVI®Conductor / HVI®long Conductor

HVI®Conductor / HVI®long ConductorHigh-voltage-resistant, insulated down conductor for keeping the separation distance to electrically conductive parts according to IEC 62305-3.

For use up to an equivalent separation distance s ≤ 75 cm (in air) or s ≤ 150 cm (solid material).

Tripod for Supporting Tubes without Lateral Outlet

Tripod for Supporting Tubes without Lateral OutletSpecial design for HVI Conductor installed inside / outside of the supporting tube, with double cleat for connection of 2x Rd 8-10 mm. For keeping the bending radius of the HVI Conductor at the tripod, two concrete bases are positioned underneath and one above the brace. Adjustable to the roof inclination up to max. 10°. The stackable concrete base (Part No. 102 010) and the support plate (Part No. 102 050) have to be ordered separately.

Tripods for Supporting Tubes with Lateral Outlet

Tripods for Supporting Tubes with Lateral OutletSpecial design for HVI Conductor installed inside the supporting tube, with lateral outlet and double cleat for connection of 2x Rd 8-10 mm. Adjustable to the roof inclination up to max. 5°

The stackable concrete base (Part No. 102 010) and the support plate (Part No. 102 050) as well as the threaded rod sets (Part No. 105 396-105 398 or Part No. 105 496-105 498) have to be ordered separately.

Stripping Tool for HVI®light Conductors / HVI®Conductors

Stripping Tool for HVI®light Conductors / HVI®ConductorsTool for stripping the semi-conductive sheath and the PE insulation of the HVI light Conductor, HVI Conductor (outer diameter 20 mm). Tool consists of a handle and various exchangeable cutting heads Stripping length of HVI light Conductor, HVI Conductor is adjustable in steps of 0.2 mm (lock points) by the set screw in the handle and is shown on the handle scale

Handling
Apply the cutting head at the conductor end and turn clockwise with light pressure for cutting / stripping. Exchange of the cutting head without tool due to the bayonet coupling.

Conductor Holder for HVI®Conductor in Ex Areas

Conductor Holder for HVI®Conductor in Ex AreasThe HVI Conductor is suitable for use in explosion hazardous areas of Ex zone 1 (gases, vapours, mists) as well as Ex zone 21 (dusts). The special installation conditions safely prevent electric sparks to neighbouring metal parts when lightning current flows through the HVI Conductor.
The HVI Conductor has to be installed in explosion hazardous areas in accordance with the installation instructions.

Cable Shears for HVI®Conductors

Cable Shears for HVI®ConductorsCable shears for easily cutting of the HVI light Conductor, HVI Conductor (outer diameter 20 / 23 mm) and HVI power Conductor (outer diameter 27 mm) and of the CUI Conductor. The special design of the cable shears also allows for a precise cutting of stranded conductors for attaching the connection elements easily.

Stripping Tool for HVI®Conductors

Stripping Tool for HVI®ConductorsTool for stripping the additional grey sheath of the HVI light Conductor and HVI Conductor. DEHNhelix consists of a handle and an exchangeable bracket (depending on the conductor diameter).

HVI®power Conductor

HVI®power ConductorHigh-voltage-resistant, insulated down conductor for maintaining the separation distance to electrically conductive parts according to IEC/EN 62305-3. For use up to an equivalent separation distance s ≤ 90 cm (in air) or s ≤ 180 cm (solid material).

Supporting Tube with HVI®power Conductor

Supporting Tube with HVI®power ConductorAesthetically appealing installation of the HVI power Conductor inside of the supporting tube with with a small wind exposed surface area. Applicable up to an equivalent separation distance s ≤ 90 cm (in air) or s ≤ 180 cm (solid building material). Conductor length to be indicated when ordering (in steps of 0.5 m).

CUI Conductor

CUI ConductorTouch voltage at down conductors can be avoided by the CUI conductor.

Stripping Tool for HVI®power Conductors

Stripping Tool for HVI®power ConductorsTool for stripping the semi-conductive sheath and the PE insulation of the HVI power Conductor (outer diameter 27 mm) Tool consisting of handle and various exchangeable cutting heads Stripping length of the HVI power Conductor is adjustable in steps of 0.2 mm (lock points) by the set screw in the handle and is shown on the handle scale

Handling
Apply the cutting head at the conductor end and turn clockwise with light pressure for cutting / stripping. Exchange of the cutting head without tool due to the bayonet coupling.

Stripping Tool for CUI-Conductors

Stripping Tool for CUI-ConductorsTool for stripping the XLPE insulated CUI Conductor (outer diameter 20 mm). Tool consists of a handle and an exchangeable cutting head Stripping length of the CUI Conductor is adjustable in steps of 0.2 mm (lock points) by the setting knob in the handle and shown on the handle scale

Handling
Apply the cutting head at the conductor end and turn clockwise with light pressure for cutting / stripping.

Our Brands
  • Siemens
  • ABB
  • Movicon
  • Omron
  • Wonderware
  • Yaskawa
  • Allen Bradley
  • GE Fanuc
  • Dehn
  • I fix
  • Schneider Electric
  • Yokogava
  • Honey Well
Shenoy's Junction, MG Road
Ernakulam, Kerala, India
0484 404 6664,
sales@ipcsautomation.com

Ram Nagar, Gandhipuram
Coimbatore, TN, India
04224223664, 9585526664
sales@ipcsautomation.com

Railway Link Road,
Calicut, Kerala, India
0495 - 401 6664, 3236034,
sales@ipcsautomation.com

Sector 15, Vashi,
Navi Mumbai, India
+91 9539 09 6664
sales@ipcsautomation.com
Villa No. 30, Wadi Al Raha Street,
Nuaija (43), Doha - Qatar
00974 66526664, 30012909
sales@ipcsautomation.com