Coordinated Type 1 Lightning Current Arresters |  Type 1 Combined Lightning Current and Surge Arresters |  Type 1 Lightning Current Arresters |  Accessory for Type 1 Arresters |  N-PE Lightning Current Arresters |  Type 2 Surge Arresters |  Type 3 Surge Arresters |  International |  General accessories |  Voltage Controlled Short-Circuiting Device |  Isolating spark gaps |  Measuring and test equipment |  SDS |  Medium-voltage arrester

Coordinated Type 1 Lightning Current Arresters Suppliers

Thanks to their high efficiency, coordinated spark-gap-based type 1 lightning current arresters are ideally suited for installation in the main distribution board of low-voltage consumer’s installations.

DEHNsolid

DEHNsolidCoordinated and spark-gap-based single-pole lightning current arrester for protecting low-voltage consumer's installations against surges and even direct lightning strikes. For installation in conformity with the lightning protection zone concept at the boundaries from 0A – 1. Type 1 SPD classification according to EN 61643-11 Extremely high lightning current discharge capacity up to 200 kA Low voltage protection level UP ≤ 2.5 kV Extremely robust design for installation on busbars or mounting plates Direct connection to the busbar or connection by means of a flexible cable with cable lug

DEHNbloc® M

DEHNbloc® MCoordinated modular single-pole lightning current arrester for protecting low-voltage consumer´s installations against surges and even direct lightning strikes. For installation in conformity with the lightning protection zones concept at the boundaries from 0A – 1. SPD Type 1 according to EN 61643-11 Consisting of a base part and plug-in protection modules Maximum system availability due to RADAX Flow follow current limitation No tripping of 32 A gL/gG fuses up to short-circuit currents of 50 kArms Directly coordinated with DEHNguard surge protective devices without additional cable length Double terminal for series connection Multifunctional terminals for connecting conductors and busbars Operating state/fault indication by indicator flag in the inspection window Easy replacement of protection modules without tools due to module locking system with module release button

DEHNbloc® Maxi

DEHNbloc® MaxiCoordinated lightning current arrester for protecting low-voltage consumer’s installations against surges and even direct lightning strikes. For installation in conformity with the lightning protection zones concept at the boundaries from 0A – 1. SPD Type 1 according to EN 61643-11 Encapsulated RADAX Flow spark gap with high follow current limitation No tripping of 32 A gL/gG fuses up to short-circuit currents of 50 kArms High lightning current discharge capacity: 25 kA (10/350 µs) Directly coordinated with DEHNguard ... and V(A) NH ... surge protective devices without additional cable length NH00 versions Low voltage protection level ≤ 2.5 kV Maximum system availability

DEHNbloc® Maxi 1 CI 440 / 760 FM

DEHNbloc® Maxi 1 CI 440 / 760 FMCoordinated lightning current arrester with integrated backup fuse For protecting low-voltage consumer's installations against surges and even direct lightning strikes. For installation in conformity with the lightning protection zone concept at the boundaries from 0A - 1. Type 1 SPD according to EN 61643-11 Spark-gap-based lightning current arrester with integrated lightning current carrying backup fuse in a compact enclosure Power-side overcurrent protection not required Encapsulated spark gap without venting means Maximum system availability thanks to RADAX Flow technology Energy coordination with other arresters of the Red/Line product family Operating state / fault indication by green / red indicator flag in the inspection window With remote signalling contact for monitoring device (floating changeover contact) Mounting bracket included for flexible installation directly on the mounting plate; DIN rail mounting mandatory

DEHNbloc® Maxi 440 / 760

DEHNbloc® Maxi 440 / 760Coordinated lightning current arrester for protecting low-voltage consumer´s installations against surges and even direct lightning strikes. For installation in conformity with the lightning protection zones concept at the boundaries from 0A – 1. SPD Type 1 according to EN 61643-11 Encapsulated non-exhausting spark gap High follow current extinguishing capability and follow current limitation due RADAX Flow technology Directly coordinated with DEHNguard surge protective devices without additional cable length Operating state/fault indication by indicator flag in the inspection window ...FM version available with three-pole terminal set for connecting the remote indication

DEHNbloc® Maxi S

DEHNbloc® Maxi SCoordinated lightning current arrester with integrated backup fuse for busbars for protecting low-voltage consumer´s installations against surges and even direct lightning strikes. For installation in conformity with the lightning protection zone concept at the boundaries from 0A – 1. SPD Type 1 according to EN 61643-11 Combination of spark gap and backup fuse Directly mounted onto PEN/N busbars Low voltage protection level UP ≤ 25 kV (80 cm connecting cable included) Directly coordinated with DEHNguard surge protective device without additional cable length Short-circuit withstand capability of 100 kArms (220 kApeak) High follow current extinguishing capability and follow current limitation due to RADAX Flow technology High lightning current discharge capacity With optical-fibre interface for arrester monitoring

DEHNsecure modular

DEHNsecure modularFor protecting d.c. consumer's installations against surges and even direct lightning strikes. For installation in conformity with the lightning protection zones concept at the boundaries from 0A – 1. Type 1 SPD classification according to EN 61643-11 Coordinated spark-gap-based lightning current arrester consisting of a base part and plug-in protection module Spark gap technology particularly suited for use in d.c. circuits Operating state / fault indication by green / red indicator flag in the inspection window Easy replacement of protection modules due to module release button DSE M 1 242 (FM) version ideally suited for safety lighting systems (d.c. + a.c. operation)

Our Brands
  • Siemens
  • ABB
  • Movicon
  • Omron
  • Wonderware
  • Yaskawa
  • Allen Bradley
  • GE Fanuc
  • Dehn
  • I fix
  • Schneider Electric
  • Yokogava
  • Honey Well
Shenoy's Junction, MG Road
Ernakulam, Kerala, India
0484 404 6664,
sales@ipcsautomation.com

Ram Nagar, Gandhipuram
Coimbatore, TN, India
04224223664, 9585526664
sales@ipcsautomation.com

Railway Link Road,
Calicut, Kerala, India
0495 - 401 6664, 3236034,
sales@ipcsautomation.com

Sector 15, Vashi,
Navi Mumbai, India
+91 9539 09 6664
sales@ipcsautomation.com
Villa No. 30, Wadi Al Raha Street,
Nuaija (43), Doha - Qatar
00974 66526664, 30012909
sales@ipcsautomation.com

© IPCS Automation. All rights reserved. Web Designing Company Zentrix Technologies